Medical Device Recall: Z-0022-2007

FDA Recalls dataset · Firm: Medtronic Neuromodulation · Status: Terminated

Recall Action Class: N/A Date Initiated: 2006-06-06 Recall record compiled from public FDA source records.

Recall Parameters & Description

Normalized public record details for FDA recall code Z-0022-2007.

Recall Res Number
Z-0022-2007
Recalling Firm / Manufacturer
FEI Number
2182207
Recall Status
Terminated
Recall Classification
N/A
Date Initiated
2006-06-06
Date Posted
2006-10-20
Date Terminated
2010-07-06
Product Code
LKK
Event Number
35595
Product Quantity
4,317 pumps
Product Description Medtronic SynchroMed EL Programmable Pumps, Models 8627-10, 8627-18, 8627L-10, 8627L-18. The implantable Medtronic SynchroMed EL Programmable Pump is part of the SynchroMed EL Infusion System designed to contain and administer parenteral drugs to a specific site. The implantable components of the SynchroMed EL Infusion System include the pump with or without a side catheter access port, catheters, and catheter accessories.

Reason for Recall The Catheter Access Port (CAP) on SynchroMed EL pumps manufactured between March and July 1999 may detach from the main body of the pump, which can interrupt drug flow to the target site.

Action Details An Urgent medical Device Recall letter was sent to healthcare providers beginning June 06, 2006. The letter describes the issue, patient risk, identifies affected devices, and provides patient Management recommendations. The letter also asks for a response card to be returned to Medtronic. Patients may contact Medtronic Neurological Patient Services at 1-800-510-6735.

Distribution Pattern Worldwide distribution ---- including USA, Argentina, Barbados, Canada, Germany, India, Ireland, Italy, Mexico, The Netherlands, Spain, Switzerland, and United Kingdom.

Code Information / Serial Numbers Model 8627-10, serial numbers: NGE000001 - NGE000242R .  Model 8627-18, serial numbers: NGF000001 - NGF003266R.  Model 8627L-10, serial numbers: NGG000001R - NGG000068R,  Model 8627L-18, serial numbers: NGH000001R - NGH001780R.

Related Establishments / Registrations

Public Record Disclaimer

This page represents an index of public-record FDA device recalls. It does not imply current safety or compliance status of the product. AvaSpecs is a private aggregator and is not affiliated with the FDA or any government agency. This page does not constitute medical, safety, legal, regulatory, or compliance advice. Refer to official government sources for primary safety alerts.