Public Record Profile Registrations: 0 510(k) filings: 0 Recalls: 6

Known Identifiers & Locations

FEI Numbers 1000160240
Owner Operator Numbers N/A
Locations Covered N/A

Registered Establishments (0)

No device registration and listing records found for this entity.

510(k) Premarket Notifications (0)

No 510(k) notifications found for this entity.

FDA Recall History (6)

Recall # Product Description Initiation Date Status Action
Z-0039-2010 Infant Manual Pulmonary Resuscitator with reservoir bag, face mask & Gas sampling elbow. Product ID # 5801, 12-8713, 732-E, and 2206. Packaged under the name of Dynarex, Evergreen, Mada and Hospitak. Recalled codes may be identified by examining the patient valve housing immediately below the right-angle exhalation port, where the retention ring should be visible. MPR units with a clear or transparent ring, as well as those where no ring can be seen, should be returned. MPR units with a blue retention ring are not affected and do not need to be returned. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details
Z-0040-2010 Pediatric Manual Pulmonary Resuscitator with reservoir bag, face mask & Gas sampling elbow. Product ID #s: 5804; 12-8709, 727-E; 727MM, 2203. Packaged under the name of Dynarex, Evergreen, Mada and Hospitak. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details
Z-0041-2010 Adult Manual Pulmonary Resuscitator with reservoir tube, face mask & Gas Sampling elbow. Product ID # 5807; 12-8703, 723-E (Foreign Distribution only), 723MM. Packaged under the name of Dynarex and Evergreen. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details
Z-0042-2010 Adult Manual Pulmonary Resuscitator with reservoir bag, face mask & Gas sampling elbow. Product ID #s 5808, 12-8704; 724-E; 724MM, 32612. Packaged under the name of Dynarex, Evergreen, Hospitak and Select Medical Products. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details
Z-0043-2010 Adult Manual Pulmonary Resuscitator with reservoir tube, face mask & standard elbow. Product ID #: 12-8702; 778500; 721-E, 778500; 2200; 2201, 86-721E, 40-116722 (foreign distributiuon only), 721MM. Packaged under the name of Evergreen, Hospitak, Kentron, McKesson and Mada. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details
Z-0044-2010 Manual Pulmonary Resuscitator, Adult w/ Large Adult Mask & Reservoir Bag. Product # 12-8705. Packaged under the name of Evergreen. Reason: In some Manual Pulmonary Resuscitator units the duckbill valve and retention ring inside the patient valve housing may become dislodged and fall into the MPR bag/body. If this occurs, the MPR may lose its ability to generate the positive pressure necessary necessary to ventilate the patient. 2009-10-06 Terminated View Details